Cooper-Atkins® 480-0-8 DualTemp Infrared Thermometer & Probe

Item #: 133403
Model #: 480-0-8
Manufacturer: Cooper-Atkins

This DualTemp infrared thermometer lets you accurately measure both surface temperatures without contact and internal temperatures using the built-in retractable thermocouple probe. It has a measurement range of -27°F to 428°F.

$87.32
Availability

In Stock

 Each
Add to Cart

Description
+ -
This DualTemp infrared thermometer lets you accurately measure both surface temperatures without contact and internal temperatures using the built-in retractable thermocouple probe. It has a measurement range of -27°F to 428°F, plus min/max memory, a lock function for long term monitoring, 15 second temperature hold, and auto shutoff to conserve battery life.
  • -27°F to 428°F temperature range
  • Min/max memory
  • Has lock function for long term monitoring
  • F/C switchable
  • 1:1 D:S ratio
  • 0.95 default emissivity, adjustable 0.1 to 1
  • Uses CR2032 Lithium battery, has low battery indicator
  • 4.5" shaft length
  • 0.125" shaft diameter
  • Model #: 480-0-8
  • Hazmat: No
  • Oversize: No
  • Each Width: 1.68
  • Country Of Origin: China
  • CE Approved: Yes
  • Each Weight: 0.16
  • UPC: 070131604804
  • Each Height: 6.2
ABOUT COOPER-ATKINS

Cooper-Atkins is a manufacturer and provider of quality restaurant timers, digital thermometers, refrigerator / freezer thermometers, meat thermometers, thermocouples and hygrometers. As an innovative global partners, they deliver measuring systems to help customers ensure safe food and healthy indoor environments.

Literature
+ -
Attachments (  1 - 2 of 2  )

Pattern
+ -
COMPANION ITEMS
Reviews
+ -
Write a Review
By: kitche
From: chicago,IL
Nov 02, 2010

Cooper-Atkins® 480-0-8 DualTemp Infrared Thermometer & Probe
Works quickly and easily however after folding probe several hundred times it does become weak and act erratic.

Primary Use:
Q & A
+ -
Ask a Question
By:
From:

Oct 12, 2010
QUESTION
how do i change between two tempature?

ANSWER
You can press the Scan(infrared) button that will directly enter the non contact infrared thermometer function. Pressing the Scan(probe) button, it will directly enter the Contact thermometer function. The manual has been added to the literature button if you have further questions. Thank you.
By: Sandy
From: Seattle, wa

Dec 26, 2010
QUESTION
how do you fix Er 9 on the cooper duel temp 480?

ANSWER
You may need to reset the thermometer. To reset the 480 turn the instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn on. If the error message remains, please contact the Service Department, at Cooper Atkinds, for further assistance. Thank you.
By: martin
From: aruba

Feb 09, 2012
QUESTION
i have an error 5 and he turns himself off. can u help me with this problem?

ANSWER
Hi. You may need to reset the thermometer. To reset the 480 turn the instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn on. If the error message remains, please contact the Service Department, at Cooper Atkins, for further assistance. There is a manual in Literature tab here too. Thank you.
By: Dupree
From: capron va.

Jul 19, 2013
QUESTION
how do i switch from celius to farenhiet on this product ?

ANSWER
Hi! If you click on the "Literature" Tab on the item page there is an operating manual which has instructions on how to switch the Celsius/Fahrenheit Modes. Thanks!
By: elwin
From: Manila,Phils

Nov 18, 2015
QUESTION
How to calibrate the Cooper Atkins 480-0-8 DualTemp digital thermometer?

ANSWER
Hello, this model does not require calibration. Thank you!
By: Nicole
From: Victoria

Sep 26, 2017
QUESTION
Hello, I recently purchased one of your Cooper Dual 480 Thermometers for one of my food safe departments. When doing a calibration test today, I was able to get the Probe portion to read a correct temperature, but the laser was approximately 4° off of what it should be. I tried to see how the thermometer could be re-calibrated, but it looks as if though it cannot. Just wondering if there is actually a way as it is odd that one method would be reading correctly and they other not. Thank you for you time.

ANSWER
You can try to reset the 480 thermometer. To reset, turn the instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn on. If it is still giving an inaccurate reading please contact please contact Wasserstrom customer service at 1-866-634-8927.
Accessories
+ -
COMPANION ITEMS
Parts
+ -
COMPANION ITEMS
Video
+ -
 
Email
  • © 2018  Wasserstrom Restaurant Supply. All rights Reserved.
  • Wasserstrom is an Equal Opportunity Employer. | Privacy Policy